Aluminium Anodizing Types Equipment
Anodizing aluminum is not one process — it is a family of electrolytic processes with different equipment scopes, coating properties and applications. Type II sulfuric anodizing, hard anodizing (Type

The four anodizing types
Type | Electrolyte | Temperature | Current density | Coating thickness | Application |
|---|---|---|---|---|---|
Type II (sulfuric) | 15–20% H₂SO₄ | 18–22°C | 1.2–1.8 A/dm² | 5–25 µm | General decorative and protective |
Type III (hard) | 10–15% H₂SO₄ | 0–5°C (refrigerated) | 2.5–4.0 A/dm² | 25–150 µm | Wear resistance, insulation |
Chromic | 3–5% CrO₃ | 35–40°C | 0.3–0.5 A/dm² | 2–8 µm | Aerospace — minimal fatigue impact |
Thin-film / phosphoric | 3–12% H₃PO₄ | Room | 0.6–1.2 A/dm² | < 1 µm | Pre-adhesion for bonding and plating |
What differs in equipment scope
Equipment | Type II | Type III (hard) | Chromic |
|---|---|---|---|
Tank material | PP or 316L stainless with cathodes | PP or 316L stainless | PVC or lined steel (chromic acid attacks PP) |
Temperature control | Cooling to 18–22°C (chiller or cooling coils) | Refrigerated cooling to 0–5°C — the biggest cost differentiator | Heating to 35–40°C |
Rectifier | Constant current at 1.2–1.8 A/dm²; standard ripple spec | Higher current density; pulse capability may improve coating quality | Lower current; voltage control to prevent burning |
Fume extraction | Standard acid extraction | Standard acid extraction | Cr(VI) mist extraction and scrubbers mandatory |
Effluent treatment | Aluminum and acid neutralisation | Aluminum and acid neutralisation at higher loads | Cr(VI) reduction before discharge |
Cathodes | Aluminum or lead | Aluminum | Lead or stainless |
Hard anodizing: the temperature is the process
Chromic anodizing: the authorisation question
Key takeaways
- Type II sulfuric is the general-purpose anodising process with the simplest equipment scope.
- Hard anodizing requires refrigerated cooling to 0–5°C — the chiller is the biggest equipment investment.
- Chromic anodizing is inside the REACH authorisation regime — STAA is the alternative being adopted.
- Rectifier type: constant current mode is standard for all anodising types.
- Each type needs different cathode materials, electrolyte chemistry and effluent treatment.
Your next five steps
- Identify the anodising type your application requires: Type II, Type III, chromic or thin-film.
- Size the chiller for Type III hard anodizing — it is the largest single equipment item.
- Confirm the electrolyte chemistry and cathode material with your supplier.
- Define the rectifier specification: constant current mode at the recommended current density.
- Scope the effluent treatment: aluminum plus acid for Type II/III; Cr(VI) reduction for chromic.